You’ve bled the radiator, and it hissed for a second, but the bottom half is still cold.
As plumbers for over 20 years, it’s one of the calls we get most often once the heating comes back on in autumn, and the bleed key won’t fix it in this situation.
But why is this happening? The short answer is that a radiator that’s hot along the top and cold along the bottom has sludge sitting in it.
What The Sludge Actually Is
Inside a heating system, the steel in your radiators slowly corrodes. The by-product is magnetite, a fine black iron oxide that looks and feels like wet graphite. It’s heavier than water, so it drifts down and settles along the bottom of each panel where the flow is slowest.
As it builds up, the water stops reaching the lower half and takes the easy route across the top instead. That’s why the radiator feels hot near the valves and cold along the bottom edge, and the room never quite gets comfortable no matter how high you turn the thermostat.
Cold At The Top Is A Different Problem
Where the cold patch sits tells you most of what you need to know. For example, cold at the top with the bottom warm is trapped air, which rises, and a few seconds with a bleed key sorts it (our guide on how to bleed a radiator covers that properly).
However, a radiator that’s cold all over while the rest of the house is warm points elsewhere, and the first thing to check is whether the TRV pin has stuck down after a summer of not moving. If it hasn’t, the lockshield valve may be closed too far (our post on a radiator not heating up goes through both).
How To Check For Sludge Yourself
If you want to test for sludge, put the heating on and give it 20 minutes. Once heated, run your hand slowly up from the bottom edge of the radiator. A clear line a few inches up, where warm suddenly turns to cold, is the classic sludge pattern.
Then hold a cloth or cup under the bleed valve and open it a quarter turn. If what comes out is black or dark grey, that’s magnetite, and if it’s in one radiator it’s in all of them. Orange-brown water is rust from the radiator itself, which is more serious and comes up again below.
Another clue: if you’re bleeding the same radiator every few weeks, the gas coming out probably isn’t air. Corrosion inside steel radiators produces hydrogen, so a radiator that keeps filling with gas is corroding faster than it should.
Why It Matters Beyond One Cold Room
Sludge doesn’t just stay in the radiators. It circulates through the pump and the boiler’s heat exchanger, where the waterways are narrow, and that’s where it does the real damage.
A partly blocked heat exchanger overheats in spots, and you’ll hear it as kettling, a rumbling or ticking from the boiler when the heating fires up. Pumps seize on it too, and plenty of boiler faults we’re called out to turn out to have their cause sitting in the system water.
Houses with microbore pipework, the thin 8mm and 10mm pipe common in homes plumbed in the 1970s and 80s, block far more easily. A system like that can go from one cold radiator to several in a single winter.
A system that keeps losing pressure makes things worse. Every top-up through the filling loop brings in fresh, oxygenated water, and oxygen is what drives the corrosion. If you’re repressurising regularly, always try to find the leak first.

How It Gets Fixed
If it’s one radiator and the rest of the house heats evenly, that radiator can come off the wall and be flushed through with a hose outside. It’s a reasonable job for a confident DIYer with plenty of old towels, though it only treats the symptom.
When more than one radiator is affected, or the bleed water comes out black, the whole system needs cleaning. A power flush pumps high-flow water and cleaning chemical through each radiator in turn, lifting the magnetite and sending it to drain until the water runs clear. We then dose the system with inhibitor, which slows the corrosion back down.
The part people skip is the filter. A magnetic filter such as an Adey MagnaClean or Fernox TF1 sits on the return pipe to the boiler and catches magnetite as it circulates. Flush a system without one, and the sludge starts building again straight away. With one fitted, it gets emptied at the annual boiler service, and you can see exactly how much it’s caught.
When The Radiator Isn’t Worth Saving
However, a flush won’t help a radiator that’s corroded through.
Look along the bottom seam and around the valve tails. Rust spots or weeping pinholes there mean the steel is going from the inside, and cleaning it can open those holes up. At that point, a new radiator is cheaper than chasing leaks, and our radiator installation page covers what’s involved.
If you’re replacing radiators, get the system flushed first. New panels fitted to dirty water start corroding the day they go on.
Getting It Sorted
A radiator that’s cold at the bottom is rarely urgent, but it tells you what’s happening throughout the system, and it’s far cheaper to deal with now than after it’s reached the boiler.
We’re Cardiff plumbers with over 1,250 five-star Google reviews, and we carry out power flushing and filter fitting across Cardiff and the Vale of Glamorgan.
If your radiators are cold at the bottom, get in touch, and we’ll tell you whether it’s a single radiator job or the whole system.